Hydrogen

Nitrogen
PSA  Membrane

Zero air, Ultra zero air et      Pur air

Air dryers

Compressors

Chillers

Accessories

 

 

For more informations on our  products application  field, go and see our guide !

 

 

AIR PURIFICATORS : 
Zero Air, Ultra Zero Air , Pur Air

·         Zero Air

 

Download PDF file !

 

Informations

Download here Acrobat Reader!

 

SPECIFICATIONS / BENEFITS

·         Purity  HC < 0.05 ppm
             CO < 0.05 ppm

·         Range of flow rate : 1,5 à 6 L/min

·         Quick and easy servicing 

·         External clean and dry air compressor required

·         Improved analytical performance : the reduction of methane ( CH4) to less than 0.1 ppm reduces background noise and improves the base line stability.

·         Increased efficiency in the laboratory

·         Improved safety

·         Economy

·         Simple installation

Note : this unit can be combine with hydrogen    generator

APPLICATION

Produce laboratory grade purified and hydrocarbon free air from an existing in house oil free compressed air supply.

Eliminates the need for inconvenient high pressure cylinders.  it is ideal for use with :

§  GC-FID, NPD, FPD

§  THA

OPERATING MODE 

The pretreated air passes through a coalescing filter to eliminate oil, water and the particles higher than 5 microns. The hydrocarbons including methane are removed by oxidation on a  platinium/palladium catalyst heated . A particle filter  at  the exit of the catalyst, makes it possible to eliminate the residual particles from outgoing flow.

If your compressed air is not treated, chooses : Ultra Zero Air which integrates a treatment of the air upstream or looks into our range of air dryers.

Download documentation in PDF format !

Information on Price and Delivery

Cliquez ici pour télécharger Acrobat Reader !

 

·         ULTRA Zero Air

Download PDF file !

 

Informations

Download here Acrobat Reader!

 

 

SPECIFICATIONS / BENEFITS

·         Purity achieved : CO, HCs <0,05 ppm ; CH4, NOx, SO2, O3 < 0,5 ppm ; CO2 < 5 ppm ; Water pressure dewpoint < - 50°C

·         Range of flow rate : 1,5 to 50 L/min

 

§         Option: Integral oil free air compressor

Allows to be franked from any network. This range of generator has an acceptable sound level within a laboratory (< 55 dB).

 

§         Easy and quick maintenance :

 Equipped with filters of high efficiency, limiting considerably the maintenance, some minutes only to change internal filters and silencer.

 

* OTHER OPTIONS:
-Oxygen analyser
-Catalyst module for hydrocarbons level< 0.05ppm

* Auto start

* Alarm display with help menu

* Audible alarm sounder

* Outlet flow indicator

* Trend graphs for QA reporting

* Compressor over temperature alarm

* Remote acess to screen using internet or GSM

* Energy saving Mode
The generator has a real-time calendar and clock which can be easily updated no matter where you are in the World. By using the Auto-Run function you can select when the generator runs giving you complete control of your gas supply and saving energy.
Example: If your laboratory working hours is 8am to 6pm, set the generator to start at 5am to ensure you have high quality gas at 8am and have it switch off at 7pm, reducing running time and energy by some 55%.

APPLICATION

Produce laboratory high quality air  from an existing in house oil free compressed air supply.

Eliminates the need for inconvenient high pressure cylinders. it is ideal for use with :

§  GC-FID, NPD, FPD

§  THA

§  GC-ATD

§  Electronical nose

§  Calibration  of test machine

 

OPERATING MODE

This purifier uses a process in 5 stages to purify the ambient air in  high quality  air.

This purification unit integrates a pre and post filtration , an air dryer , a catalyst and  an activated carbon cartridge.

Supply with a control board allowing to control the correct operation of the system.

 

Download documentation in PDF format !

Information on Price and Delivery

Cliquez ici pour télécharger Acrobat Reader !

 

·         PUR AIR

Air Pur

 

SPECIFICATIONS / BENEFITS

·         PSA Technology

·         Integrated air compressor : noise level (< 52db)

·         Flow rate : 3L / min et 6L/min

·         Purity achieved : HCs < 0,1 ppm and water dewpoint  < - 40°C

·         Increased safety in the lab compare to the use of high pressure cylinders

·         Easy to install

·         Hour run meter

·         Quick and easy servicing : needs to change filter and silencer once a year

APPLICATION

Eliminate the need for costly , inconvenient high pressure cylinders in the laboratory

Including an integrated oil free air compressor, the Pure Air generator delivers a continuous stream of pure air, ideal for application such as :

§  GC-FID, NPD, FPD

§  Total hydrocarbon analyser

 

OPERATING MODE 

Ce générateur d'air pur travaille sur le principe de l’adsorption par balancement de pression. Cette technique fait appel à deux colonnes remplies d’alumine activée. Les colonnes alternent entre le mode de purification et régénération afin de purifier l’air comprimé.

Download documentation in PDF format !

Information on Price and Delivery

Click here to download Acrobat Reader !

   

 

F-DBS - SIREN 490 399 037 RCS EVRY

La Maison des Services, Avenue des 2 lacs, Courtabœuf 7, Villejust, 91971 Courtabœuf CEDEX - FRANCE

Tel: +33 (0)1.60.47.89.30 - Fax: +33 (0)1.60.47.14.50

E-mail : info@f-dbs.com -  Site : www.f-dbs.com